Scielo RSS <![CDATA[Innovations Implant Journal]]> http://revodonto.bvsalud.org/rss.php?pid=1984-596020100003&lang=pt vol. 5 num. 3 lang. pt <![CDATA[SciELO Logo]]> http://revodonto.bvsalud.org/img/en/fbpelogp.gif http://revodonto.bvsalud.org <![CDATA[<b>Conjecturas sobre a implantodontia atual</b>]]> http://revodonto.bvsalud.org/scielo.php?script=sci_arttext&pid=S1984-59602010000300001&lng=pt&nrm=iso&tlng=pt <![CDATA[<b>Qual o custo de um mini-implante?</b>]]> http://revodonto.bvsalud.org/scielo.php?script=sci_arttext&pid=S1984-59602010000300002&lng=pt&nrm=iso&tlng=pt <![CDATA[<b>Análise da capacidade sensorial mastigatória de pacientes com próteses sobre implantes</b>]]> http://revodonto.bvsalud.org/scielo.php?script=sci_arttext&pid=S1984-59602010000300003&lng=pt&nrm=iso&tlng=pt Um dos requisitos de sucesso para as próteses sobre implante é a satisfação estética e funcional. Esta pode ser avaliada objetivamente medindo a análise protéica do sangue e urina e subjetivamente o tamanhos das partículas processadas na mastigação e questionário de sensibilidade mastigatória pré e pós prótese instalada. Este trabalho avaliou o ultimo tópico apresentando questionário de sensibilidade que varia de 0 a 2 e do prontuário de atendimento no qual foi feito levantamento de dados de próteses unitárias parciais e removíveis e sua capacidade de mastigar alimentos sólidos suaves e duros no qual foram aplicados testes estatísticos. Observou que a maioria dos casos é de mulheres entre 60 a 69 anos, que existia diferença na sensibilidade de mastigação entre diferentes tipos de alimentos. Todos os pacientes apresentavam melhoras da capacidade sensorial de interpretar os alimentos independente da prótese, quanto maior a estabilidade do trabalho protético maior o índice de eficiência e sensibilidade mastigatória.<hr/>One of the requirements for successfull on implant prostheses is thee esthetic and functional satisfaction. This can be objectively evaluated by measuring the protein analysis of blood and urine and subjectively the particle sizes processed sensitivity and masticatory questionnaire before and after prosthesis installed. This study evaluated the questionnaire last topic featuring a sensitivity ranging from 0 to 2 and the records of service, in which data collection was made prosthesis, partial and removable unit and its ability to chew soft and hard solid element on which tests were used statistics. He noted that most cases are in women aged 60 to 69 years, that there was difference in sensitivity between different types of chewing food. All patients showed improvements in sensory capacity of food independent of the protheses. The greater stability of the prosthetic work, the largest index of masticatory eficienty and sensibility. <![CDATA[<b>Resistência à tração de coroas de NiCr cimentadas sobre munhões de liga de titânio, com 4 diferentes tipos de cimentos</b>]]> http://revodonto.bvsalud.org/scielo.php?script=sci_arttext&pid=S1984-59602010000300004&lng=pt&nrm=iso&tlng=pt Neste trabalho de resistência à tração foi avaliada a eficiência de 4 agentes cimentantes (fosfato de zinco S. S. White, ionômero de vidro Ketac Cem Easymix, resina composta/ionômero de vidro RelyX Luting 2 e resina acrílica especial Panavia 21 TC) usados para fixar coroas totais de NiCr a munhões tronco-cônicos, usinados em liga de Ti-6Al-4V. Foram utilizados 40 munhões, distribuídos em grupos de 10, para cada material. Os ensaios mecânicos foram realizados em uma máquina universal MTS 810, na velocidade de 0,5 mm/min. A respectiva Análise de Variância (ANOVA) apontou existir diferença significante entre os grupos e o teste de Tukey (p < 0,05) também mostrou diferenças significantes entre eles, exceto nas comparações fosfato versus RelyX e fosfato versus Ketac Cem. O melhor desempenho foi apresentado pela resina Panavia 21 (1.127,996 N); a resina composta/ionômero de vidro RelyX (478,197 N) mostrou comportamento similar apenas ao do fosfato (430,662 N), o qual apresentou desempenho semelhante ao ionômero de vidro Ketac Cem (227,705 N).<hr/>In this work of tensile strength was evaluated the efficacy of 4 cements (S. S. White zinc phoshate, Ketac Cem Easymix glass ionomer, RelyX Luting 2 composite resin/glass ionomer and Panavia 21 TC special acrylic resin) used to fix NiCr crowns to usinated titanium alloy abutments. Were used 40 abutments distributed in groups of 10 elements, to each material. The mechanical essays were developed at a MTS 810 universal machine, adjusted to a 0.5 mm/m velocity. The ANOVA applied to data pointed out the existence of significant differences between groups; the subsequent Tukey´s test (p<0.05) also detected significant differences, except at comparisons of phosphate versus RelyX and phosphate versus Ketac Cem. The better performance was presented by Panavia 21 (1,127.996 N); RelyX (478.197 N) showed itself similar only to phosphate (430.662 N), wich had a performance similar to that of Ketac Cem (227.705 N). <![CDATA[<b>Ensaio de corrosão galvânica de placas e parafusos de titânio usados na fixação interna rígida</b>]]> http://revodonto.bvsalud.org/scielo.php?script=sci_arttext&pid=S1984-59602010000300005&lng=pt&nrm=iso&tlng=pt O titânio comercialmente puro é o material mais usado atualmente para a fabricação de implantes de reconstrução, isso porque é um material altamente biocompatível com os tecidos vivos dos mamíferos. O objetivo principal deste trabalho é realizar ensaio de corrosão galvânica segundo a norma ASTM G71 (98), de dois matérias em contato elétrico em solução de 0,9% de cloreto de sódio (NaCl) com temperatura de 37 ºC. Este trabalho apresenta características e resultados de ensaios realizados em placas e parafusos usados na fixação interna rígida, com o propósito de avaliar a resistência à corrosão do titânio ASTM F67 e ASTM F136.<hr/>Commercially pure titanium is the material most widely used for the manufacture of implants for reconstruction, because it is a material highly biocompatible with living tissues of mammals. The main objective of this work is galvanic corrosion test according to ASTM G71 (98), two substances in electrical contact in a solution of 0.9% sodium chloride (NaCl) at 37 ºC. This paper presents features and results of tests carried out on plates and screws used in rigid internal fixation in order to evaluate the corrosion resistance of titanium ASTM F67 and ASTM F136. <![CDATA[<b>Análise comparativa da percepção estética entre estudantes de odontologia e seus pacientes em relação à seleção de cor e forma de dentes artificiais</b>]]> http://revodonto.bvsalud.org/scielo.php?script=sci_arttext&pid=S1984-59602010000300006&lng=pt&nrm=iso&tlng=pt A presente pesquisa teve por objetivo analisar a percepção estética entre estudantes de odontologia e seus pacientes em relação à seleção da cor e forma de dentes artificiais e avaliar a aplicabilidade clínica da régua TTI - Trubyte Tooth Indicator (Dentsply, York, PA, Estados Unidos), a qual se propõe a determinar as proporções do incisivo central superior e a classificação das formas faciais. Participaram deste estudo 60 pacientes dentados, de 19 a 59 anos e 60 estudantes de odontologia, de 18 a 25 anos. Ambos responderam a um questionário sobre seleção de dentes, e nos pacientes foram realizadas fotos da face com a utilização da régua para análise das medidas e formas faciais, como também foi mensurada com paquímetro digital a altura e largura do incisivo central esquerdo superior. As medidas obtidas através da régua foram comparadas com as proporções reais dos dentes naturais dos pacientes. Os resultados mostraram uma preferência por dentes da forma ovóide, tanto pelos alunos (51,7%), como pelo pacientes (46,7%); em relação à cor, houve uma preferência pela cor 1A, tanto por pacientes (55%) como pelos alunos (31,7%). Houve concordância entre a escolha da forma do dente pelo aluno e a forma da face do paciente observada através da régua Trubyte Tooth Indicator. Não houve diferença estatística entre os dois métodos na comparação da largura dos dentes. Observou-se, pela amostra avaliada, que o instrumento Trubyte Tooth Indicator pode ser utilizado como um meio auxiliar na seleção da largura dos dentes artificiais.<hr/>The aim of this work was to analyze the aesthetics perception among dental students and their patients in relation to color and shape of prosthetic teeth, and the practice applicability of the Trubyte Tooth Indicator - TTI (Dentsply, York, PA, United States) guide, in correlation of measures and classification of patients' faces. Sixty patients dentate were 19 to 59 years old and 60 dental students were 18 to 25 years old participated in this study. Every one had answered a questionnaire on teeth selection, and only the pictures of the patients were made with the use of device for face measures analysis, as well the height and width of upper left incisor was measured with a digital caliper. The results showed that a preference for ovoid form teeth as by students (51.7%) as by patients (46.7%); with regards to color there was a preference for 1A color as by patients (55%) as by students (31.7%). There was concordance between choice of the tooth form by student and the patient face form observed through Trubyte Tooth Indicator guide. There were no differences between both methods comparing width of the teeth. For assessed sample, it was concluded that the Trubyte Tooth Indicator guide is able to be used as an auxiliary means in selecting width of artificial teeth. <![CDATA[<b>Revisão sistemática sobre o uso de células-tronco mesenquimais em terapias de perdas ósseas</b>]]> http://revodonto.bvsalud.org/scielo.php?script=sci_arttext&pid=S1984-59602010000300007&lng=pt&nrm=iso&tlng=pt Terapias de perdas ósseas com células-tronco mesenquimais sugerem uma promissora perspectiva de uso em cirurgias orais reconstrutivas. O objetivo deste estudo foi realizar um levantamento bibliográfico dos últimos 15 anos com trabalhos experimentais temáticos para traçar um perfil de metodologias e resultados alcançados nesta área. Um destacável crescimento de publicações ocorreu em países economicamente desenvolvidos. A medula óssea se mantém como a principal fonte tecidual de células-tronco mesenquimais (79,31%), caracterizadas por adesão, imunofenotipagem e multipotência, capazes de promover a osteogênese in vitro. Embora exista pluralidade de modelos experimentais in vivo (espécies animais) e clínicos (sítios anatômicos), há prevalência de testes pré-clínicos de terapia celular (27,03%), que indicam boa bicompatibilidade tecidual e osteogênese aumentada pós-enxerto. Estudos clínicos têm relatado resultados positivos para o tratamento de defeitos periodontais, rebordo alveolar deficiente, fenda alveolar congênita, defeitos cranianos extensos, levantamento de seio maxilar e atrofia mandibular pós-irradiação. Os biomateriais carreadores de células mais utilizados foram biocerâmicas a base de hidroxiapatita (11,16%), seguidos por polímeros a base de colágeno (5,42%) ou poliácido lático (5,30%) e compósitos baseados em fosfatos de cálcio (3,71%). Conclui-se que a utilização de células-tronco mesenquimais representa novos e eficazes procedimentos terapêuticos para regeneração óssea em Odontologia e Medicina.<hr/>Bone loss therapies using mesenchymal stem cells suggest a promising prospect for use in oral reconstructive surgeries. The aim of this study was to review the literature of the past 15 years with experimental theme to draw a profile of methodologies and results achieved in this area. A remarkable growth of publications occurred in economically developed countries. The bone marrow remains the main source of tissue mesenchymal stem cells (79.31%), characterized by adherence, immunophenotyping and multipotency, which can promote osteogenesis in vitro. Although there is a plurality of experimental models in vivo (animal species) and clinical studies (anatomical sites), there is prevalence of preclinical trials of cell therapy (27.03%), indicating good tissue biocompatibility and the highest osteogenesis after graft. Clinical studies have related positive results in the treatment of periodontal defects, alveolar ridge deficiency, congenital alveolar cleft, extensive cranial defects, maxillary sinus lifting and mandibular atrophy after radiation. The most used biomaterials as cell carriers were hydroxyapatite-based bioceramics (11.16%) followed by collagen- (5.42%) or poly lactic acid- (5.30%) based polymers and calcium phosphates-based composites (3.71%). We concluded that the use of mesenchymal stem cells represent new and effective therapeutic tools for bone regeneration in dentistry and medicine. <![CDATA[<b>Comparação entre resultados de testes experimentais com a simulação numérica pelo método de elementos finitos em placas de cirurgia buco maxilo facial</b>]]> http://revodonto.bvsalud.org/scielo.php?script=sci_arttext&pid=S1984-59602010000300008&lng=pt&nrm=iso&tlng=pt Neste trabalho é apresentado o estudo comparativo de placas buco maxilo facial para reconstrução com o proposito de avaliar a durabilidade e resistência do produto. A utilização de placas e parafusos de titânio no tratamento dos traumas e deformidades buco maxilo facial vem aumentando, à medida que novas pesquisas comprovam sua eficácia e segurança em relação a outras técnicas utilizadas anteriormente. O objetivo principal deste trabalho é comparar as propriedades mecânicas das placas, buco maxilo facial, fabricados com titânio, por meio de simulação numérica utilizando o método de elementos finitos com os resultados obtidos de forma experimental. A metodologia empregada nesta pesquisa é de caráter exploratório, foi desenvolvida, a partir de testes experimentais e simulações computacionais.<hr/>This paper presents a comparative study of oral and maxillofacial reconstruction plates with the purpose to evaluate the durability and strength of the product. The use of plates and screws in the treatment of trauma and maxillofacial deformities is increasing, as new research supports its efficacy and safety compared with other techniques used previously. O main objective is to compare the mechanical properties of the plates, maxillofacial manufactured from titanium, through numerical simulation using the finite element method with the results obtained experimentally. The methodology used in this research is exploratory, was developed from experimental tests and computer simulations. <![CDATA[<b>Análise da interface cilindro protético e intermediário com duas técnicas de fundição</b>]]> http://revodonto.bvsalud.org/scielo.php?script=sci_arttext&pid=S1984-59602010000300009&lng=pt&nrm=iso&tlng=pt A dificuldade de se obter uma infraestrutura metálica em monobloco com assentamento passivo é muito difícil. A conexão forçada da estrutura metálica da prótese implanto-retida pode resultar em micro-fraturas do tecido ósseo, zonas de isquemia marginal, fraturas dos componentes protéticos. O objetivo deste estudo foi avaliar a adaptação passiva das estruturas metálicas sobre implantes, nas interfaces intermediários e cilindros protéticos, com a técnica de fundição sobre análogos (Grupo I), e fundição segmentada pós-brasagem (Grupo II ). As interfaces foram analisadas por microscopia eletrônica de varredura, e os resultados mostraram para o teste t de Student, que o Grupo I apresentou desajuste com média de 95,5 µm, e desvio padrão de 64,3 µm, e o Grupo II desajuste com média de 86,5 µm, e desvio padrão de 54,2 µm. Conclui-se que não houve diferença estatisticamente significante para as duas técnicas de fundição analisadas.<hr/>The difficulty of getting an infrastructure metallic pumps with passive fit is too difficult. To force the connection of the metallic structure of the implant-retained may result in micro-fractures on bone, marginal zone of ischemia and fractures of prosthetic components. The aim of this study was to evaluate the passive fit of implant metal structures, interfaces and intermediate prosthetic cylinders, with the casting technique over similar ones (Group I), and casting targeted post-brazing (Group II). The interfaces were analyzed by scanning electron microscopy, and the results showed for the Student t test, the group I had a mismatch with a mean of 95.5 micrometres and standard deviation of 64.3 micrometres and group II misfit with an average of 86.5 micrometers, and standard deviation of 54.2 micrometers. It is concluded that there was no statistically significant difference for both of casting techniques analyzed. <![CDATA[<b>Enxerto ósseo em odontologia</b>: <b>revisão de literatura</b>]]> http://revodonto.bvsalud.org/scielo.php?script=sci_arttext&pid=S1984-59602010000300010&lng=pt&nrm=iso&tlng=pt O osso é um tecido conjuntivo especializado, vascularizado e dinâmico que se modifica ao longo da vida do organismo. Quando lesado, possui uma capacidade única de regeneração e reparação sem a presença de cicatrizes, mas em algumas situações devido ao tamanho do defeito, o tecido ósseo não se regenera por completo Assim, se faz necessária a realização de procedimentos de enxertia óssea. Haja vista, existem diversos tipos de enxertos e diversas áreas doadoras. Diante disso, o objetivo do presente estudo foi realizar uma revisão de literatura a cerca dos tipos de enxertos mais empregados na odontologia. Tendo em vista a importância das reconstruções ósseas na cirurgia bucomaxilofacial, torna-se necessário conhecer a viabilidade e a influência dos biomateriais, associados ou não a enxertos autógenos, na reparação óssea. Mesmo este, apresentando inúmeras qualidades, estudos ainda devem ser feitos a fim de obter a cada dia, um material sintético compatível com o tecido ósseo perdido em quantidades adequadas sem necessitar de cirurgias extra-bucais que consagradamente são consideradas de maior morbidade.<hr/>Bone is a specialized connective tissue, vascular and dynamic changes over the life of the organism. When injured, has a unique ability to regenerate and repair without the presence of scars, but in some situations due to the size of the defect, the bone tissue does not regenerate so completely, it is necessary to carry out bone grafting procedures. Considering there are various types of grafts and various donor sites. Thus, the aim of this study was to review the literature to some type of graft most commonly used in dentistry. Given the importance of bone reconstruction in oral and maxillofacial surgery, it is necessary to know the viability and influence of biomaterials, or not associated with autogenous grafts in bone repair. Even this, with many qualities, but further studies should be done to achieve each day, a synthetic material compatible with bone tissue lost in adequate amounts without requiring extra-oral surgeries that are considered to be devoted to higher morbidity. <![CDATA[<b>Passividade da prótese sobre implante</b>]]> http://revodonto.bvsalud.org/scielo.php?script=sci_arttext&pid=S1984-59602010000300011&lng=pt&nrm=iso&tlng=pt Prótese com adaptação passiva significa que esta pode ser parafusada sem que tensões sejam geradas. Uma estrutura sem passividade sobre o tecido ósseo pode até levar à perda da osseointegração; assim, adaptação passiva foi definida como o nível que não causaria qualquer complicação clínica. O objetivo deste trabalho foi avaliar os artigos sobre a passividade das infra-estruturas metálicas e quais os melhores métodos laboratoriais que deveriam ser adotados para serem realizados de forma que possam ser considerados os seus resultados clínicos de significância satisfatória. Um ajuste passivo é um requisito importante para próteses implanto-suportadas. Isso limita a quantidade de estresse transferido para a interface osso-implante e garante osseointegração a longo prazo, pois o assentamento passivo absoluto é difícil de obter. O profissional deve realizar os procedimentos de laboratório corretos ou quando necessário seccionar da prótese e soldar as partes com precisão para não haver distorção.<hr/>Prosthesis with passive adaptation means that it can be screwed without tensions are generated. A structure without liability on the bone tissue may even lead to loss of osseointegration so passive adaptation was defined as the level that would not cause any clinical complication. The aim of this study was to evaluate the articles about the passivity of the metallic infrastructure, and what better laboratory methods that should be adopted to be performed so that might be considered the results satisfactory clinical significance. A passive fit is an important prerequisite for implant-supported prostheses. It limits the amount of stress transferred to the bone-implant interface and ensures long-term osseointegration, because the absolute passive fit is difficult to obtain. The clinician should perform laboratory procedures as necessary or proper sectioning of the prosthesis and weld parts with accuracy to no distortion. <![CDATA[<b>Uso de malha de titânio no tratamento de fraturas de assoalho de órbita</b>: <b>relato de caso</b>]]> http://revodonto.bvsalud.org/scielo.php?script=sci_arttext&pid=S1984-59602010000300012&lng=pt&nrm=iso&tlng=pt As fraturas do osso zigomático são traumatismos faciais comuns e representam ou as fraturas mais comuns ou a segunda em frequência, após as fraturas nasais. A incidência, etiologia, idade e predisposição por sexo nas fraturas zigomáticas varia de acordo com o status social, econômico, político e educacional da população estudada. Devido ao fato que o contorno facial é influenciado pelas estruturas ósseas subjacentes, o zigoma representa um papel fundamental no contorno facial. A alteração da posição do zigoma também tem um grande significado funcional, pois cria alterações oculares e na função mandibular. A terapia adequada para o trauma de órbita é sempre complexa e requer que o cirurgião esteja familiarizado com a anatomia detalhada da órbita e o padrão de dano dos componentes de tecido moles e duros. Vários materiais aloplásticos são usados no reparo de fraturas da parede orbitária. Reparo da fratura orbital que usa malha de titânio proporciona reprodução estável e segura da parede de órbita, enquanto oferece resultados funcionais e cosméticos excelentes, comparáveis com outros materiais de aloplásticos. Apresentamos um caso de fratura de assoalho de órbita tratada com malha de titânio pré-fabricada. A malha de titânio é um material muito seguro para reconstrução de fraturas blow out e restauração do volume da órbita.<hr/>Zygomatic fractures are common facial injuries, representing either the most common facial fracture or the second in frequency after nasal fractures. The incidence, etiology, age, and sex predilection of zygomatic injuries vary, depending largely on the social, economic, political, and educational status of the population studied. Since the gross shape of the face is influenced largely by the underlying osseous structure, the zygoma plays an important role in facial contour. Disruption of zygomatic position also has great functional significance because it creates impairment of ocular and mandibular function. Trauma to the orbit is always complex, and adequate therapy requires that the surgeon be familiar with the detailed anatomy of the orbit and the pattern of injury of the soft and hard tissue components. Various alloplastic materials are used in orbital wall reconstruction. Orbital fracture repair using mesh titanium orbital implants provides reliable and reproducible stabilization of orbital wall defects, while offering outstanding functional and cosmetic results comparable with other alloplastic materials. We present a case report of blow out fracture treated which prefabricated titanium mesh in their repair. Mesh titanium implant is a very reliable material for reconstruction of the orbital blow-out fractures and restoration of the orbital volume. <![CDATA[<b>Barra de titânio pré-fabricada para prótese implantossuportada do tipo protocolo carga imediata</b>: <b>relato de caso clínico</b>]]> http://revodonto.bvsalud.org/scielo.php?script=sci_arttext&pid=S1984-59602010000300013&lng=pt&nrm=iso&tlng=pt A estabilidade primária dos implantes é um fator importante para o sucesso da osseointegração e fundamenta a aplicação das barras pré-fabricadas em mandíbulas edêntulas quando do uso de carga imediata. No entanto em algumas situações esta alternativa de tratamento não está indicada, devendo o profissional conhecer as características anatômicas do arco do paciente para ter segurança em utilizar a barra pré-fabricada. O presente artigo tem o objetivo de descrever um caso clínico utilizando uma barra pré-fabricada em mandíbula edêntula preparada para receber uma prótese implantossuportada do tipo protocolo carga imediata com acompanhamento clínico de 2 anos. Foi utilizado o sistema Neopronto (Neodent Implante Osseointegrável, Neodent, Curitiba, PR, Brasil) para direcionar paralelamente 4 implantes inter-foraminais e facilitar a instalação imediata da prótese protocolo. Pode-se constatar que a utilização da técnica da barra pré-fabricada é uma alternativa viável de tratamento para mandíbulas edêntulas, pois permite um nível da adaptação e passividade previsíveis, reduzindo o tempo clínico. Entretanto, sua indicação é precisa para casos em que o formato do arco do paciente se adapte perfeitamente a técnica.<hr/>The primary stability of implants is an important factor for osseointegration successful and justifies the application of prefabricated bars in edentulous mandible when the use of immediate loading. However in some situations this alternative treatment is not indicated, and the professional know the anatomic characteristics of the arch of the patient to have safety in using prefabricated bar. The purpose of this article was to describe a clinical report using a prefabricated bar in edentulous mandible prepared to receive an immediate loading implant-supported prosthesis type protocol with clinical follow-up of 2 years. The Neopronto system (Neodent Implante Osseointegrável, Neodent, Curitiba, PR, Brazil) was used to drive four parallel inter-foraminal implants and facilitate the installation of the immediate loading prosthesis. It can be conclude that the use of this prefabricated bar technique is a viable alternative treatment for edentulous mandible, because it allows a level of adaptability and passivity predictable, reducing clinical time. However, his indication is accurate for cases in which the shape of the arch of the patient perfectly suits technique. <![CDATA[<b>Linha de implantes Revolution</b>]]> http://revodonto.bvsalud.org/scielo.php?script=sci_arttext&pid=S1984-59602010000300014&lng=pt&nrm=iso&tlng=pt Este trabalho apresenta a linha de implantes Revolution. São feitas considerações sobre sua compatibilidade com o sistema Brånemark de hexágono externo. A etapa de projeto compreende a simulação em elementos finitos, os testes de protótipos e o acompanhamento dos lotes pilotos. Os resultados destas análises e testes são apresentados. É fornecida uma visão geral sobre o sistema produtivo da SIN - Sistema de Implante (São Paulo, SP, Brasil) contemplando aspectos ligados à fabricação do produto em si e do controle de qualidade envolvido em todas as etapas. A linha de implantes Revolution atende e até supera todas as exigências normativas e de qualidade impostas pelos órgãos normativos, pelo mercado.<hr/>This paper presents the Revolution implants line. It compares the system compatibility with Brånemark external hex. The design atage includes the finite element simulation, prototype testing and monitoring of pilot batches. The results of these reviews and tests are presented. It provided an overview on the production system of the SIN - Sistema de Implante (São Paulo, SP, Brazil) contemplating aspects of manufacturing the product itself and the quality control involved in all stages. The Revolution implant line meets and even exceeds all regulatory requirements and quality imposed by regulatory bodies, the marketplace. <![CDATA[<b>Avaliação de implante dental comprometido empregando microscopia eletrônica de varredura e espectrometria dispersiva de raio X</b>]]> http://revodonto.bvsalud.org/scielo.php?script=sci_arttext&pid=S1984-59602010000300015&lng=pt&nrm=iso&tlng=pt O sucesso e durabilidade dos implantes dentais são observados na maior parte dos tratamentos para reposição de dentes, entretanto, algumas fallhas, relatadas na literatura, podem comprometer a reabilitação dos pacientes. Um paciente de 46 anos de idade foi reabilitado com uma prótese clássica de Brånemark, entretanto, um implante da região anterior da mandíbula, que sustentava a mesma, após 18 meses da instalação apresentou mobilidade, dor, e exsudação, sendo necessária sua remoção. O processo de osseointegração se dá entre as superfícies ósseas e óxidos formados sobre a superfície do titânio comercialmente puro, utilizado na fabricação dos implantes dentais. Entretanto, agentes contaminantes podem se desprender da camada superficial dos implantes, potencializar a resposta inflamatória e alterar o processo de cicatrização, o que pode levar à perda do implante. Com o objetivo de avaliar a presença de possíveis contaminantes na superfície do implante perdido, o mesmo foi encaminhado ao Centro de Caracterização e Desenvolvimento de Materiais (CCDM) para análise, por microscopia eletrônica de varredura e espectrometria dispersiva de raio X (MEV/EDS). Verificou-se a presença de elementos, como C, Ca, Na, Cl e Si. Esses elementos podem ser originários dos fluidos corporais ou dos processos finais de fabricação, não sendo possível, pelas técnicas utilizadas, estabelecer sua origem.<hr/>The success and durability of dental implants are observed in the most part of treatments to replace missing teeth, however, some failures of them, described in the literature, can compromise the patient's rehabilitation. A 46-years-old patient was rehabilitated with a Brånemark classical prosthesis. However one implant in the anterior region of the mandible, that sustained the prosthesis, after 18 months of the installation showed mobility, pain and exsudation, being necessary to retrieve it. The osseointegration process is established between bone tissue and oxides formed on surface of commercially pure titanium, used in the manufacture of the dental implants. However, contaminants agents can be released from superficial layer of dental implants, potencialize inflammatory response and modify the healing process, causing dental implant loss. Aiming to evaluate the presence of possible contaminants in the surface of the lost dental implant, it was sent to CCDM for analysis by using scanning electron microscopy and energy-dispersive spectrometer X-ray (SEM/EDS). It was verified the presence of elements, as C, P, Ca, Na, Cl, Si. These elements can be originated from body fluids or final stages of manufacture, not being possible, for the used techniques to conclude their origin.