<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1981-8637</journal-id>
<journal-title><![CDATA[RGO.Revista Gaúcha de Odontologia (Online)]]></journal-title>
<abbrev-journal-title><![CDATA[RGO, Rev. gaúch. odontol. (Online)]]></abbrev-journal-title>
<issn>1981-8637</issn>
<publisher>
<publisher-name><![CDATA[Mundi Brasil Gráfica e Editora Ltda.]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1981-86372010000200016</article-id>
<title-group>
<article-title xml:lang="pt"><![CDATA[Infiltração bacteriana na interface implante/pilar: considerações ao implantodontista]]></article-title>
<article-title xml:lang="en"><![CDATA[Bacterial leakage of the implant-abutment interface: what the implantologist should know]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Lopes]]></surname>
<given-names><![CDATA[Alex Casati]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rezende]]></surname>
<given-names><![CDATA[Carlos Eduardo Edwards]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Fernandes]]></surname>
<given-names><![CDATA[Mariana dos Santos]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Weinfeld]]></surname>
<given-names><![CDATA[Ilan]]></given-names>
</name>
<xref ref-type="aff" rid="A04"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Associação Brasileira de Odontologia Regional ABC  ]]></institution>
<addr-line><![CDATA[São Paulo SP]]></addr-line>
<country>Brasil</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Associação Brasileira de Odontologia Regional ABC  ]]></institution>
<addr-line><![CDATA[Santo Amaro SP]]></addr-line>
<country>Brasil</country>
</aff>
<aff id="A03">
<institution><![CDATA[,Universidade Metodista de São Paulo Faculdade de Odontologia ]]></institution>
<addr-line><![CDATA[São Paulo SP]]></addr-line>
<country>Brasil</country>
</aff>
<aff id="A04">
<institution><![CDATA[,Universidade de São Paulo Faculdade de Odontologia ]]></institution>
<addr-line><![CDATA[São Paulo SP]]></addr-line>
<country>Brasil</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2010</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2010</year>
</pub-date>
<volume>58</volume>
<numero>2</numero>
<fpage>239</fpage>
<lpage>242</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://revodonto.bvsalud.org/scielo.php?script=sci_arttext&amp;pid=S1981-86372010000200016&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://revodonto.bvsalud.org/scielo.php?script=sci_abstract&amp;pid=S1981-86372010000200016&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://revodonto.bvsalud.org/scielo.php?script=sci_pdf&amp;pid=S1981-86372010000200016&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="pt"><p><![CDATA[Diversos estudos têm mostrado altas frequências de sucesso na reabilitação oral por meio de implantes dentários. Entretanto, podem ocorrer fracassos por complicações logo após a sua instalação ou, posteriormente, quando a prótese sobre o implante já está em função há algum tempo. As falhas tardias podem ocorrer em situações nas quais a osseointegração de um implante previamente estável e em função é perdida por sobrecarga e/ou infecção, sendo que, um dos fatores de infecção é a infiltração de bactérias através de falhas existentes na conexão implante/pilar. Com essas considerações, o objetivo deste trabalho foi, de por meio de uma revisão de literatura discorrer sobre a infiltração de fluídos e bactérias no interior dos implantes, que ocorre devido à falha na conexão implante/pilar protético. Concluiu-se que mesmo com o desenvolvimento de novos implantes e pilares e a tentativa de alguns autores de buscarem o vedamento dessa microfissura a infiltração bacteriana entre implante/pilar não foi evitada.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Many studies have shown high rates of successful oral rehabilitation with implants. However, complications may occur immediately after the implant is placed or some time later, when the prosthesis has already been used for some time. These complications may lead to implant failure. Late failures can happen in situations where the osseointegration of a previously stable and functional implant is lost because of an overload and/or an infection. One of the causes of infection is the infiltration of bacteria in failures present in the implant-abutment interface. With this in mind, the purpose of this study was to address the infiltration of liquids and bacteria inside the implant due to failures in the implant-abutment interface based on a literature review. In conclusion, despite the development of new implants and abutments and the attempts of some authors to seal microfissures, bacterial infiltration in the implant-abutment interface still occurred.]]></p></abstract>
<kwd-group>
<kwd lng="pt"><![CDATA[implante dentário]]></kwd>
<kwd lng="pt"><![CDATA[infecções bacterianas]]></kwd>
<kwd lng="pt"><![CDATA[periodontia]]></kwd>
<kwd lng="en"><![CDATA[dental implantation]]></kwd>
<kwd lng="en"><![CDATA[bacterial infections]]></kwd>
<kwd lng="en"><![CDATA[periodontics]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="right"><font size="2" face="Verdana"><b>REVIS&Atilde;O</b> REVIEW</font></p>     <p align="right">&nbsp;</p>     <p><font size="4" face="verdana"><b><a name="tx"></a>Infiltra&ccedil;&atilde;o bacteriana na interface implante/pilar: considera&ccedil;&otilde;es ao implantodontista</b></font></p>     <p>&nbsp;</p>     <p><font size="3" face="Verdana"><b>Bacterial leakage of the implant&#45;abutment interface: what the implantologist should know</b></font></p>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font size="2" face="Verdana"><b>Alex Casati Lopes<sup>I,</sup> <a href="#nt"><sup>*</sup></a>; Carlos Eduardo Edwards Rezende<sup>II</sup>; Mariana dos Santos Fernandes<sup>III</sup>; Ilan Weinfeld<sup>IV</sup></b></font></p>     <p><font size="2" face="Verdana"><sup>I</sup>Associa&ccedil;&atilde;o Brasileira de Odontologia Regional ABC. Rua Baraldi, 662, Centro, 09510&#45;000, S&atilde;o Caetano do Sul, S&atilde;o Paulo, SP, Brasil    <br>  <sup>II</sup>Universidade Santo Amaro, Programa de P&oacute;s&#45;Gradua&ccedil;&atilde;o em Implantodontia. Santo Amaro, SP, Brasil    ]]></body>
<body><![CDATA[<br>  <sup>III</sup>Universidade Metodista de S&atilde;o Paulo, Faculdade de Odontologia. S&atilde;o Paulo, SP, Brasil    <br>  <sup>IV</sup> Universidade de S&atilde;o Paulo, Faculdade de Odontologia. S&atilde;o Paulo, SP, Brasil</font></p>     <p>&nbsp;</p>     <p>&nbsp;</p> <hr size="1" noshade>     <p><font size="2" face="Verdana"><b>RESUMO</b></font></p>     <p><font size="2" face="Verdana">Diversos estudos t&ecirc;m mostrado altas frequ&ecirc;ncias de sucesso na reabilita&ccedil;&atilde;o oral por meio de implantes dent&aacute;rios. Entretanto, podem ocorrer fracassos por complica&ccedil;&otilde;es logo ap&oacute;s a sua instala&ccedil;&atilde;o ou, posteriormente, quando a pr&oacute;tese sobre o implante j&aacute; est&aacute; em fun&ccedil;&atilde;o h&aacute; algum tempo. As falhas tardias podem ocorrer em situa&ccedil;&otilde;es nas quais a osseointegra&ccedil;&atilde;o de um implante previamente est&aacute;vel e em fun&ccedil;&atilde;o &eacute; perdida por sobrecarga e/ou infec&ccedil;&atilde;o, sendo que, um dos fatores de infec&ccedil;&atilde;o &eacute; a infiltra&ccedil;&atilde;o de bact&eacute;rias atrav&eacute;s de falhas existentes na conex&atilde;o implante/pilar. Com essas considera&ccedil;&otilde;es, o objetivo deste trabalho foi, de por meio de uma revis&atilde;o de literatura discorrer sobre a infiltra&ccedil;&atilde;o de flu&iacute;dos e bact&eacute;rias no interior dos implantes, que ocorre devido &agrave; falha na conex&atilde;o implante/pilar prot&eacute;tico. Concluiu&#45;se que mesmo com o desenvolvimento de novos implantes e pilares e a tentativa de alguns autores de buscarem o vedamento dessa microfissura a infiltra&ccedil;&atilde;o bacteriana entre implante/pilar n&atilde;o foi evitada.</font></p>     <p><font size="2" face="Verdana"><B>Termos de indexa&ccedil;&atilde;o:</B> implante dent&aacute;rio; infec&ccedil;&otilde;es bacterianas; periodontia.</font></p> <hr size="1" noshade>     <p><font size="2" face="Verdana"><b>ABSTRACT</b></font></p>     <p><font size="2" face="Verdana">Many studies have shown high rates of successful oral rehabilitation with implants. However, complications may occur immediately after the implant is placed or some time later, when the prosthesis has already been used for some time. These complications may lead to implant failure. Late failures can happen in situations where the osseointegration of a previously stable and functional implant is lost because of an overload and/or an infection. One of the causes of infection is the infiltration of bacteria in failures present in the implant&#45;abutment interface. With this in mind, the purpose of this study was to address the infiltration of liquids and bacteria inside the implant due to failures in the implant&#45;abutment interface based on a literature review. In conclusion, despite the development of new implants and abutments and the attempts of some authors to seal microfissures, bacterial infiltration in the implant&#45;abutment interface still occurred. </font></p>     <p><font size="2" face="Verdana"><B>Indexing terms:</B> dental implantation; bacterial infections; periodontics.</font></p> <hr size="1" noshade>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p>&nbsp;</p>     <p><font size="3" face="verdana"><b>INTRODU&Ccedil;&Atilde;O</b></font></p>     <p><font size="2" face="Verdana">A perda de um dente para o paciente pode envolver, al&eacute;m de um problema funcional, um problema psicol&oacute;gico associado ao comprometimento est&eacute;tico. O desenvolvimento tecnol&oacute;gico em diversas &aacute;reas, em especial na implantodontia, proporcionou aos pacientes novas alternativas de reabilita&ccedil;&atilde;o. Atualmente, existem no mercado in&uacute;meros tipos de desenhos e di&acirc;metros de implantes e tratamentos para atender as diversas &aacute;reas ed&ecirc;ntulas com os seus diferentes tipos de osso. Do mesmo modo, diversas formas e materiais de pilares intermedi&aacute;rios foram desenvolvidos no intuito de atender as necessidades cl&iacute;nicas de cada caso.</font></p>     <p><font size="2" face="Verdana">Muitos s&atilde;o os fatores que podem favorecer o desenvolvimento da doen&ccedil;a periimplantar dentre eles, a doen&ccedil;a periodontal preexistente, defici&ecirc;ncia na higiene bucal, a topografia da superf&iacute;cie e o desenho do implante. Como os implantes dent&aacute;rios n&atilde;o s&atilde;o totalmente cobertos pelos tecidos periodontais, parte deles ficam expostos ao ambiente bucal, sendo facilmente colonizado pelo biofilme formado pela microbiota bucal. Alguns membros suplementares dessa microbiota podem ocasionar doen&ccedil;as periimplantares<sup>1</sup>, e posteriormente perda do implante.</font></p>     <p><font size="2" face="Verdana">Diante dessas considera&ccedil;&otilde;es, pode&#45;se dizer que a chance de contamina&ccedil;&atilde;o do implante &eacute; grande, ainda mais quando se sabe que a uni&atilde;o entre implante/conector prot&eacute;tico n&atilde;o &eacute; perfeita. Tal falha pode acarretar em infiltra&ccedil;&atilde;o de fluidos e bact&eacute;rias para o interior do implante favorecendo a coloniza&ccedil;&atilde;o bacteriana perimplantar, podendo levar a perda do selamento mucoso periimplantar, ocorrendo assim altera&ccedil;&otilde;es dos par&acirc;metros cl&iacute;nicos e microbiol&oacute;gicos dos tecidos periimplantares<sup>2&#45;3</sup>.</font></p>     <p><font size="2" face="Verdana">Clinicamente, pode&#45;se dizer que a probabilidade de contamina&ccedil;&atilde;o no interior dos implantes ocasiona odor e sabor desagrad&aacute;vel, mucosite periimplantar e periimplantite<sup>2</sup>.</font></p>     <p><font size="2" face="Verdana">Sendo assim a proposta deste trabalho foi de, por meio de uma revis&atilde;o da literatura, discorrer sobre a infiltra&ccedil;&atilde;o de flu&iacute;dos e bact&eacute;rias em diferentes tipos de implantes: os hexagonais e <I>cone&#45;morse</I>.</font></p>     <p><font size="2" face="Verdana"><I>An&aacute;lise da interface implante/pilar</I></font></p>     <p><font size="2" face="Verdana">Trabalhos de Traversy &amp; Birek<sup>4</sup> e Quirynen &amp; Van Steenberghe<sup>5</sup> ilustram infiltra&ccedil;&atilde;o de fluidos e bact&eacute;rias na interface do conjunto pilar /implante. Os primeiros demonstraram, em estudo <I>in vitro, </I>que na interface implante/pilar do sistema Br&auml;nemark ocorre infiltra&ccedil;&atilde;o bidirecional de flu&iacute;do contendo <I>Streptococcus sanguinis</I>, um dos colonizadores encontrados em grande n&uacute;mero tanto no biofilme dental como no perimplantar. J&aacute; Quirynen &amp; Van Steenberghe<sup>5</sup>, investigando a presen&ccedil;a de bact&eacute;rias no interior da fixa&ccedil;&atilde;o implante/pilar do sistema Br&auml;nemark, examinaram, por microscopia de contraste de fase diferencial, a parte apical dos dois parafusos de apoio dos pilares colocados h&aacute; tr&ecirc;s meses em nove volunt&aacute;rios, e observaram que todos abrigaram uma quantidade significativa de c&eacute;lulas bacterianas, principalmente coc&oacute;ides (86,2%), bastonetes sem mobilidade (12,3%), bastonetes m&oacute;veis (1,3%) e espiroquetas (0,1%).</font></p>     ]]></body>
<body><![CDATA[<p><font size="2" face="Verdana">Dando continuidade aos experimentos, em estudo <I>in vitro</I>, Quirynen et al.<sup>6</sup>, submergiram totalmente e parcialmente amostras de implantes do tipo Branemark<sup>&reg;</sup> durante sete dias em uma cultura de micro&#45;organismos orais, e observaram que houve passagem de bact&eacute;rias; a flora bacteriana presente foi composta desde cocos Gram&#45;positivos at&eacute; bacilos Gran&#45;negativos como <I>Fusobacterium nucleatum</I>.</font></p>     <p><font size="2" face="Verdana">Devido aos avan&ccedil;os tecnol&oacute;gicos nas pesquisas e ao desenvolvimento de meios de medi&ccedil;&atilde;o precisos, como o microsc&oacute;pio eletr&ocirc;nico de varredura, sabe&#45;se que o contato entre pilar prot&eacute;tico/implante possui um GAP que pode variar de 20</font><font>&#181;</font><font size="2" face="verdana">m a 150</font><font>&#181;</font><font size="2" face="verdana">m, analisadas em implantes tipo hex&aacute;gono externo de diferentes marcas<sup>7</sup>.</font></p>     <p><font size="2" face="Verdana">A resposta gengival frente aos pilares intermedi&aacute;rios possui papel importante na manuten&ccedil;&atilde;o da integridade do implante. Kawahara et al.<sup>8</sup> sugeriram que a ades&atilde;o do epit&eacute;lio juncional &eacute; dominante na manuten&ccedil;&atilde;o da integridade do implante dent&aacute;rio. Especificamente quanto do material, Abraamsson et al.<sup>9</sup> observaram que os pilares de tit&acirc;nio e os cer&acirc;micos permitiram a forma&ccedil;&atilde;o de epit&eacute;lio juncional ao seu redor, em contrapartida, n&atilde;o ocorreram &agrave; forma&ccedil;&atilde;o de uma inser&ccedil;&atilde;o apropriada nos pilares de ouro, havendo recess&atilde;o gengival e reabsor&ccedil;&atilde;o &oacute;ssea. </font></p>     <p><font size="2" face="Verdana">Cabe ressaltar que o pilar pode estar bem ajustado no momento da sua inser&ccedil;&atilde;o, mas em fun&ccedil;&atilde;o da carga mastigat&oacute;ria, for&ccedil;as laterais podem alterar esta uni&atilde;o, aumentando o GAP, principalmente nos sistemas de hex&aacute;gono externo. Deve&#45;se, portanto, avaliar a carga mastigat&oacute;ria, a estabilidade do parafuso de fixa&ccedil;&atilde;o da pr&oacute;tese e o torque aplicado para um melhor ajuste pilar/implante<sup>10&#45;12</sup>. </font></p>     <p><font size="2" face="Verdana">Alguns estudos indicam que a contamina&ccedil;&atilde;o interna dos implantes com pilares fixados com cimento &eacute; menor que a existente em implantes com pilares parafusados. Piatelli et al.<sup>13</sup> compararam a penetra&ccedil;&atilde;o de fluidos e bact&eacute;rias em sistemas de implantes cimentados e parafusados. E observaram uma fenda de 2</font><font>&#181;</font><font size="2" face="verdana">m a 7</font><font>&#181;</font><font size="2" face="verdana">m entre implante/pilar no sistema parafusado, enquanto que no sistema cimentado a fenda foi de 7</font><font>&#181;</font><font size="2" face="verdana">m, por&eacute;m foi totalmente preenchida pelo material de cimenta&ccedil;&atilde;o. Assim os implantes cimentados ofereceram melhores resultados em rela&ccedil;&atilde;o &agrave; permeabilidade de fluidos e bact&eacute;rias.</font></p>     <p><font size="2" face="Verdana"><I>Consequ&ecirc;ncia das falhas de adapta&ccedil;&atilde;o implante/pilar </I></font></p>     <p><font size="2" face="Verdana">Como resultado cl&iacute;nico da infiltra&ccedil;&atilde;o bacteriana, os pacientes relatam a sensa&ccedil;&atilde;o de odor e sabor desagrad&aacute;veis<sup>14</sup>, isso devido a coloniza&ccedil;&atilde;o bacteriana no interior dos implantes, onde predominam estreptococos anaer&oacute;bios e facultativos, al&eacute;m de bastonetes anaer&oacute;bios Gram&#45;positivos dos g&ecirc;neros <I>Propionibacterium, Eubacterium, Actinomyces</I> e bastonetes anaer&oacute;bios Gram&#45;negativos como os do g&ecirc;neros <I>Fusobacterium, Prevotella e Porphyromonas</I><sup>11</sup>. Esse fato pode aumentar o risco de inflama&ccedil;&atilde;o dos tecidos perimplantares<sup>12</sup>, e consequentemente compromete a estabilidade do implante<sup>15</sup>. Para Rimondini et al.<sup>16</sup> a perimplantite n&atilde;o est&aacute; relacionada a infiltra&ccedil;&atilde;o bacteriana, j&aacute; que em seu estudo tal fato n&atilde;o desencadeou inflama&ccedil;&atilde;o perimplantar, mas sim o grau de efici&ecirc;ncia da higiene oral.</font></p>     <p><font size="2" face="Verdana"><I>Tentativas de veda&ccedil;&atilde;o do GAP entre implante/pilar prot&eacute;tico</I></font></p>     <p><font size="2" face="Verdana">Para se evitar a infiltra&ccedil;&atilde;o e coloniza&ccedil;&atilde;o bacteriana dentro do implante, tem se verificado diversos estudos<sup>17&#45;20</sup> que tentaram diminuir ou at&eacute; mesmo vedar esta microfissura. Mcarthy &amp; Guckes<sup>14</sup> sugeriram como m&eacute;todo a utiliza&ccedil;&atilde;o de um cimento colocado dentro do espa&ccedil;o de acesso ao parafuso, antes da pr&oacute;tese ser parafusada. Com isso, os pacientes relataram a completa elimina&ccedil;&atilde;o do gosto desde que o cimento foi adicionado em conjunto &agrave; fixa&ccedil;&atilde;o do parafuso. Contudo tal melhora cl&iacute;nica n&atilde;o eliminou o GAP existente, sendo que a longo prazo a infiltra&ccedil;&atilde;o ocorre novamente como comprovado por Duarte et al.20, que na tentativa de veda&ccedil;&atilde;o com verniz e sil&iacute;cio de diferentes implantes, observaram a presen&ccedil;a de contamina&ccedil;&atilde;o ap&oacute;s um m&ecirc;s. Pode&#45;se justificar a conclus&atilde;o do trabalho de Mcarthy &amp; Guckes<sup>14</sup> com os resultados de Piattelli et al.13 que afirmaram que os pilares cimentados ofereceram melhores resultados em rela&ccedil;&atilde;o a permeabilidade de fluidos e bact&eacute;rias quando comparados com os pilares parafusados. Estes fatos foram muito estudados nos sistemas de conex&atilde;o hexagonal, sendo assim vasta a literatura em afirmar a ocorr&ecirc;ncia da infiltra&ccedil;&atilde;o bacteriana, assim como a tentativa de vedamento desses espa&ccedil;os<sup>7,12&#45;13,16&#45;22</sup>. </font></p>     <p><font size="2" face="Verdana">Para suprir as desvantagens das conex&otilde;es hexagonais, foi desenvolvida a conex&atilde;o do tipo cone&#45;morse, que proporcionaria &iacute;ntimo contato entre as paredes dos cones com &acirc;ngulos precisos, permitindo um torque por fric&ccedil;&atilde;o das paredes internas do cone do implante e diminuindo assim o GAP existente entre pilar/implante<sup>23&#45;24</sup>. Entretanto em v&aacute;rios estudos ficou comprovado que mesmo em conex&otilde;es do tipo cone&#45;morse as infiltra&ccedil;&otilde;es ocorreram. No trabalho de Gross et al.<sup>12</sup> a infiltra&ccedil;&atilde;o ocorreu antes dos 80 minutos de avalia&ccedil;&atilde;o. O mesmo ocorreu na pesquisa de Jansen et al.<sup>25</sup> que observaram a infltra&ccedil;&atilde;o de <I>Escherichia coli</I> 48 horas ap&oacute;s a exposi&ccedil;&atilde;o com os pat&oacute;genos em todos os implantes do tipo cone&#45;morse. Proff et al.<sup>18</sup>, relataram infiltra&ccedil;&atilde;o de <I>Porphiromonas gengivales</I>, em 24 horas ap&oacute;s a imers&atilde;o dos implantes. Harder t al.<sup>26</sup>, utilizando dois sistemas de implante (Astra Tech e Ankylos), evidenciou a contamina&ccedil;&atilde;o com endotoxinas no grupo Ankylos ap&oacute;s cinco minutos e os demais em at&eacute; 168 horas.</font></p>     ]]></body>
<body><![CDATA[<p><font size="2" face="Verdana">Analisando as propriedades da liga met&aacute;lica do abutment, Pautke et al.<sup>27</sup> perceberam que a liga de niquel&#45;tit&acirc;nio possu&iacute;a como caracter&iacute;stica principal a mem&oacute;ria de forma, ou seja, em situa&ccedil;&otilde;es termomec&acirc;nicas diferentes a tend&ecirc;ncia da liga &eacute; voltar ao formato original. Isso se deve &agrave;s altera&ccedil;&otilde;es na fase cristalina do metal, quando em baixas temperaturas alcan&ccedil;a a sua fase cristalina austen&iacute;tica, o metal se encontra mais male&aacute;vel e contra&iacute;do, em temperaturas elevadas, como a do meio bucal, o material atinge a fase martens&iacute;tica e expande. Com base nessas considera&ccedil;&otilde;es, desenvolveram abutments dessa liga acreditando que a expans&atilde;o do material vedaria o GAP. Todavia, os resultados mostraram apenas uma significante diminui&ccedil;&atilde;o da infiltra&ccedil;&atilde;o bacteriana.</font></p>     <p><font size="2" face="Verdana">Levando em considera&ccedil;&atilde;o a dimens&atilde;o bacteriana presente na flora oral, onde a m&eacute;dia varia entre 1,1 e 1,5</font><font>&#181;</font><font size="2" face="verdana">m, incluindo <I>Porphyromonas gingivalis</I> (0,5 a 2</font><font>&#181;</font><font size="2" face="verdana">m), <I>Actinobacillus actinomycetencomitans</I> (0,4 a 1,0 </font><font>&#181;</font><font size="2" face="verdana">m) e <I>Fusobacterium Nucleatum </I>(0,4 a 0,7</font><font>&#181;</font><font size="2" face="verdana">m), al&eacute;m de bact&eacute;rias como as espiroquetas, de 0,1 a 0,5</font><font>&#181;</font><font size="2" face="verdana">m<sup>28</sup>, pode&#45;se dizer que a microinfiltra&ccedil;&atilde;o no sistema implante/pilar &eacute; inevit&aacute;vel tanto nos tipos hexagonais como nos tipo cone&#45;morse. Na literatura diversos tipos de materiais como guta&#45;percha<sup>18</sup>, silicone<sup>17</sup>, vernis e silicio<sup>20</sup>, clorexidina a 2%<sup>19</sup>, guta&#45;percha e cianocrilato (SuperBonder, Loctite<sup>&reg;</sup>, S&atilde;o Paulo, Brasil)<sup>22</sup> t&ecirc;m sido testados para se fazer o vedamento. Ficou provado que tal infiltra&ccedil;&atilde;o pode ser minimizada utilizando o torque correto de acordo com cada fabricante, mas pode aumentar em casos onde o parafuso &eacute; solto e reapertado repetidamente<sup>29</sup>; o posicionamento supracrestal da interface<sup>15</sup>; com a utiliza&ccedil;&atilde;o de antiss&eacute;pticos<sup>19</sup>; al&eacute;m do desenho do implante, por&eacute;m nenhuma destas medidas impedem tal infiltra&ccedil;&atilde;o. Quanto a utiliza&ccedil;&atilde;o de intermedi&aacute;rios de fabricantes distintos, a literatura n&atilde;o aponta nenhuma diferen&ccedil;a significativa quanto &agrave; microinfiltra&ccedil;&atilde;o<sup>30</sup>.</font></p>     <p>&nbsp;</p>     <p><font size="3" face="Verdana"><b>CONSIDERA&Ccedil;&Otilde;ES FINAIS</b></font></p>     <p><font size="2" face="Verdana">Mesmo com o desenvolvimento de novos implantes e pilares e na tentativa de alguns autores proporcionarem o melhor vedamento de forma a evitar a microinfiltra&ccedil;&atilde;o, a infiltra&ccedil;&atilde;o bacteriana entre implante/pilar n&atilde;o foi, at&eacute; o momento evitada. Cabe resssaltar que o implantodontista deve tomar medidas para a diminui&ccedil;&atilde;o da coloniza&ccedil;&atilde;o bacteriana como utilizar materiais biocompat&iacute;veis e avaliar a qualidade de acabamento e adapta&ccedil;&atilde;o das pr&oacute;teses, al&eacute;m de dar o torque correto de acordo com a especifica&ccedil;&atilde;o de cada fabricante. Sugere&#45;se novos estudos com o desafio de se produzir um implante onde o contato entre implante/pilar seja t&atilde;o eficiente ou at&eacute; mesmo de se encontrar um material eficaz no velamento, a fim de se evitar infiltra&ccedil;&otilde;es de flu&iacute;dos para o interior do implante, que comprometem a durabilidade do implante, devido a doen&ccedil;as como mucosite e periimplantite bacteriana que possam ser desenvolvidas.</font></p>     <p>&nbsp;</p>     <p><font size="3" face="Verdana"><b>Colaboradores </b></font></p>     <p><font size="2" face="Verdana">AC LOPES e CEE REZENDE participaram da concep&ccedil;&atilde;o, levantamento bibliogr&aacute;fico e desenvolvimento do artigo. MS FERNANDES participou da interpreta&ccedil;&atilde;o dos dados, desenvolvimento do artigo e revis&atilde;o final. I WEINFELD foi respons&aacute;vel pela orienta&ccedil;&atilde;o. interpreta&ccedil;&atilde;o dos dados, desenvolvimento do artigo e revis&atilde;o final. </font></p>     <p>&nbsp;</p>     <p><font size="3" face="Verdana"><b>REFER&Ecirc;NCIAS</b></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p><font size="2" face="Verdana">1. Lorenzo JL, Cavenague M. Microbiologia perimplantar. In: Lorenzo JL. Microbiologia para estudante de Odontologia. S&atilde;o Paulo: Ahteneu; 2004. p.151&#45;62.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193527&pid=S1981-8637201000020001600001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">Buser D, Warrer K, Karring T. Formation of a periodontal ligament around titanium implants. J Periodontol. 1990;61(9):597&#45;601.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193529&pid=S1981-8637201000020001600002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">3. O'Mahony A, MacNeill SR, Cobb CM. Design features that may influence bacterial plaque retention: a retrospective analysis of failed implants. Quintessence Int. 2000;31(4):249&#45;56.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193531&pid=S1981-8637201000020001600003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">4. Traversy MC, Birek P. Fluid e microbial leakage of implant&#45;abutment assembly in vitro. J Dent Res. 1992;71(special issue):754.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193533&pid=S1981-8637201000020001600004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">5. Quirynen M, van Steenberghe D. Bacterial colonization of the internal part of two&#45;stage implants. An in vivo study. Clin Oral Implants Res. 1993;4(3):158&#45;61.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193535&pid=S1981-8637201000020001600005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p><font size="2" face="Verdana">6. Quirynen M, Bollen CM, Eyssen H, van Steenberghe D. Microbial penetration along the implant components of the Branemark system. An in vitro study. Clin Oral Implants Res. 1994;5(4):239&#45;44.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193537&pid=S1981-8637201000020001600006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">7. Vidigal Jr. GM. Evaluation of the implant connection interface using sanning eletron microscopy. Braz Dent J. 1995;6(1):17&#45;23.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193539&pid=S1981-8637201000020001600007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">8. Kawahara H, Kawahara D, Mimura Y, Takashima Y, Ong JL. Morphologic studies on the biologic seal of titanium dental implants. Report II. In vivo study on the defending mechanism of epithelial adhesions/attachment against invasive factors. Int J Oral Maxillofac Implants. 1998;13(4):465&#45;73.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193541&pid=S1981-8637201000020001600008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">9. Abrahamsson I, Berglundh T, Glantz PO, Lindhe J. The mucosal attachment at different abutments. An experimental study in dogs. J Clin Periodontol. 1998;25(9):721&#45;7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193543&pid=S1981-8637201000020001600009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">10. Steinebrunner L, Wolfart S, Bossmann K, Kern M. In vitro evaluation of bacterial leakage along the implant&#45;abutment interface of different implant systems. Int J Oral Maxillofac Implants. 2005;20(6):875&#45;81.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193545&pid=S1981-8637201000020001600010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p><font size="2" face="Verdana">11. Persson LG, Lekholm U, Leonhardt A, Dahlen G, Lindhe J. Bacterial colonization on internal surfaces of Branemark system implant components. Clin Oral Implants Res. 1996;7(2):90&#45;5.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193547&pid=S1981-8637201000020001600011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">12. Gross M, Abramovich I, Weiss EI. Microleakage at the abutment&#45;implant interface of osseointegrated implants: a comparative study. Int J Oral Maxillofac Implants. 1999;14(1):94&#45;100.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193549&pid=S1981-8637201000020001600012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">13. Piattelli A, Scarano A, Paolantonio M, Assenza B, Leghissa GC, Di Bonaventura G, et al. Fluids and microbial penetration in the internal part of cement&#45;retained versus screw&#45;retained implant&#45;abutment connections. J Periodontol. 2001;72(9):1146&#45;50.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193551&pid=S1981-8637201000020001600013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">14. McCarthy GR, Guckes AD. Preventing bacterial colonization associated with two types of implant abutments. J Prosthet Dent. 1993;70(5):479.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193553&pid=S1981-8637201000020001600014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">15. Cravinhos JC. An&aacute;lise in vitro da contamina&ccedil;&atilde;o bacteriana na interface implante/conector prot&eacute;tico em tr&ecirc;s sistemas de implantes end&oacute;sseos &#91;disserta&ccedil;&atilde;o&#93;. Campinas: Universidade Estadual de Campinas; 2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193555&pid=S1981-8637201000020001600015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p><font size="2" face="Verdana">16. Rimondini L, Marin C, Brunella F, Fini M. Internal contamination of a 2&#45;component implant system after occlusal loading and provisionally luted reconstruction with or without a washer device. J Periodontol. 2001;72(12):1652&#45;7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193557&pid=S1981-8637201000020001600016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">17. Sartori S. Avalia&ccedil;&atilde;o in vitro da capacidade da membrana de silicone vedar a infiltra&ccedil;&atilde;o de bact&eacute;rias periodontopatog&ecirc;nicas no micro&#45;espa&ccedil;o entre o pilar prot&eacute;tico e implantes de hex&aacute;gono externo &#91;disserta&ccedil;&atilde;o&#93;. Santo Amaro: Universidade de Santo Amaro; 2006.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193559&pid=S1981-8637201000020001600017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">18. Proff P, Steinmetz I, Bayerlein T, Dietze S, Fanghanel J, Gedrange T. Bacterial colonisation of interior implant threads with and without sealing. Folia Morphol (Warsz). 2006;65(1):75&#45;7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193561&pid=S1981-8637201000020001600018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">19. Oliani D. Avalia&ccedil;&atilde;o da efic&aacute;cia da solu&ccedil;&atilde;o de clorexidina a 2% no controle do desenvolvimento de periodontopat&oacute;genos na interface coroa&#45;pilar pro&eacute;tico em pr&oacute;teses dentais parafusadas sobre implantes &#91;disserta&ccedil;&atilde;o&#93;. Santo Amaro: Universidade de Santo Amaro; 2004.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193563&pid=S1981-8637201000020001600019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">20. Duarte AR, Rossetti PH, Rossetti LM, Torres SA, Bonachela WC. In vitro sealing ability of two materials at five different implant&#45;abutment surfaces. J Periodontol. 2006;77(11):1828&#45;32.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193565&pid=S1981-8637201000020001600020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p><font size="2" face="Verdana">21. Dibart S, Warbington M, Su MF, Skobe Z. In vitro evaluation of the implant&#45;abutment bacterial seal: the locking taper system. Int J Oral Maxillofac Implants. 2005;20(5):732&#45;7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193567&pid=S1981-8637201000020001600021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">22. Nascimento C, Barbosa RE, Issa JP, Watanabe E, Ito IY, Albuquerque RF Jr. Bacterial leakage along the implant&#45;abutment interface of premachined or cast components. Int J Oral Maxillofac Surg. 2008;37(2):177&#45;80.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193569&pid=S1981-8637201000020001600022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">23. Norton MR. An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design. Clin Oral Implants Res. 1997;8(4):290&#45;8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193571&pid=S1981-8637201000020001600023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">24. Norton MR. Assessment of cold welding properties of the internal conical interface of two commercially available implant systems. J Prosthet Dent. 1999;81(2):159&#45;66.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193573&pid=S1981-8637201000020001600024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">25. Jansen VK, Conrads G, Richter EJ. Microbial leakage and marginal fit of the implant&#45;abutment interface. Int J Oral Maxillofac Implants. 1997;12(4):527&#45;40.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193575&pid=S1981-8637201000020001600025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p><font size="2" face="Verdana">26. Harder S, Dimaczek B, Acil Y, Terheyden H, Freitag&#45;Wolf S, Kern M. Molecular leakage at implant&#45;abutment connection&#45;in vitro investigation of tightness of internal conical implant&#45;abutment connections against endotoxin penetration. Clin Oral Investig &#91;serial on the Internet&#93;. Available from: &lt;<a href="http://www.springerlink.com/content/u94808v560k31377/fulltext.pdf" target="_blank">http://www.springerlink.com/content/u94808v560k31377/fulltext.pdf</a>&gt;    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193577&pid=S1981-8637201000020001600026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref -->.</font></p>     <!-- ref --><p><font size="2" face="Verdana">27. Pautke C, Kolk A, Brokate M, Wehrstedt JC, Kneissl F, Miethke T, et al. Development of novel implant abutments using the shape memory alloy nitinol: preliminary results. Int J Oral Maxillofac Implants. 2009;24(3):477&#45;83.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193579&pid=S1981-8637201000020001600027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">28. De Lorenzo JL, Simionato MRL, Mayu MPA. Componentes da microbiota bucal. S&atilde;o Paulo: Grupo Brasileiro de Microbologia Oral; 1998.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193581&pid=S1981-8637201000020001600028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">29. Nascimento CD, Pedrazzi V, Miani PK, Moreira LD, Junior RFDA. Influence of reapeated screw tigtening on bacterial leakage along the implan&#45;abutment interface. Clin Oral Implants Res. 2009;20(12):394&#45;7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193583&pid=S1981-8637201000020001600029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p><font size="2" face="Verdana">30. Cury PR, Horewicz VV, Augusto &Acirc;O, Johy JC, Lagan&aacute; DC, Ara&uacute;jo NS. Avalia&ccedil;&atilde;o in vitro da microinfiltra&ccedil;&atilde;o bacteriana na interface impante&#45;intermedi&aacute;rio. Implant News. 2006;3(6):613&#45;7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=193585&pid=S1981-8637201000020001600030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p>&nbsp;</p>     <p><font size="2" face="Verdana">Recebido em: 18/3/2009    <br>  Aprovado em: 5/7/2009</font></p>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font size="2" face="Verdana"><a name="nt"></a><a href="#tx">*</a> Correspond&ecirc;ncia  para / <I>Correspondence to</I>: AC LOPES. <I>E&#45;mail</I>: &lt;<a href="mailto:alexcasati@terra.com.br">alexcasati@terra.com.br</a>&gt;</font></p>      ]]></body>
<back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lorenzo]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Cavenague]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="pt"><![CDATA[Microbiologia perimplantar]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Lorenzo]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
</person-group>
<source><![CDATA[Microbiologia para estudante de Odontologia]]></source>
<year>2004</year>
<page-range>151-62</page-range><publisher-loc><![CDATA[São Paulo ]]></publisher-loc>
<publisher-name><![CDATA[Ahteneu]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Buser]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Warrer]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Karring]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Formation of a periodontal ligament around titanium implants]]></article-title>
<source><![CDATA[J Periodontol.]]></source>
<year>1990</year>
<volume>61</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>597-601</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[O'Mahony]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[MacNeill]]></surname>
<given-names><![CDATA[SR]]></given-names>
</name>
<name>
<surname><![CDATA[Cobb]]></surname>
<given-names><![CDATA[CM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Design features that may influence bacterial plaque retention: a retrospective analysis of failed implants]]></article-title>
<source><![CDATA[Quintessence Int]]></source>
<year>2000</year>
<volume>31</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>249-56</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Traversy]]></surname>
<given-names><![CDATA[MC]]></given-names>
</name>
<name>
<surname><![CDATA[Birek]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fluid e microbial leakage of implant-abutment assembly in vitro]]></article-title>
<source><![CDATA[J Dent Res.]]></source>
<year>1992</year>
<volume>71</volume>
<page-range>754</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Quirynen]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[van Steenberghe]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bacterial colonization of the internal part of two-stage implants: An in vivo study]]></article-title>
<source><![CDATA[Clin Oral Implants Res]]></source>
<year>1993</year>
<volume>4</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>158-61</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Quirynen]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Bollen]]></surname>
<given-names><![CDATA[CM]]></given-names>
</name>
<name>
<surname><![CDATA[Eyssen]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[van Steenberghe]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microbial penetration along the implant components of the Branemark system: An in vitro study]]></article-title>
<source><![CDATA[Clin Oral Implants Res]]></source>
<year>1994</year>
<volume>5</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>239-44</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vidigal Jr]]></surname>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[GM: Evaluation of the implant connection interface using sanning eletron microscopy]]></article-title>
<source><![CDATA[Braz Dent J]]></source>
<year>1995</year>
<volume>6</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>17-23</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kawahara]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Kawahara]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Mimura]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Takashima]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Ong]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Morphologic studies on the biologic seal of titanium dental implants: Report II. In vivo study on the defending mechanism of epithelial adhesions/attachment against invasive factors]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>1998</year>
<volume>13</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>465-73</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Abrahamsson]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Berglundh]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Glantz]]></surname>
<given-names><![CDATA[PO]]></given-names>
</name>
<name>
<surname><![CDATA[Lindhe]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The mucosal attachment at different abutments: An experimental study in dogs]]></article-title>
<source><![CDATA[J Clin Periodontol]]></source>
<year>1998</year>
<volume>25</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>721-7</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Steinebrunner]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Wolfart]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Bossmann]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Kern]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>2005</year>
<volume>20</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>875-81</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Persson]]></surname>
<given-names><![CDATA[LG]]></given-names>
</name>
<name>
<surname><![CDATA[Lekholm]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Leonhardt]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Dahlen]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Lindhe]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bacterial colonization on internal surfaces of Branemark system implant components]]></article-title>
<source><![CDATA[Clin Oral Implants Res]]></source>
<year>1996</year>
<volume>7</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>90-5</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gross]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Abramovich]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Weiss]]></surname>
<given-names><![CDATA[EI]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microleakage at the abutment-implant interface of osseointegrated implants: a comparative study]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>1999</year>
<volume>14</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>94-100</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Piattelli]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Scarano]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Paolantonio]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Assenza]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Leghissa]]></surname>
<given-names><![CDATA[GC]]></given-names>
</name>
<name>
<surname><![CDATA[Di Bonaventura]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fluids and microbial penetration in the internal part of cement-retained versus screw-retained implant-abutment connections]]></article-title>
<source><![CDATA[J Periodontol]]></source>
<year>2001</year>
<volume>72</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>1146-50</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McCarthy]]></surname>
<given-names><![CDATA[GR]]></given-names>
</name>
<name>
<surname><![CDATA[Guckes]]></surname>
<given-names><![CDATA[AD]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Preventing bacterial colonization associated with two types of implant abutments]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1993</year>
<volume>70</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>479</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cravinhos]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
</person-group>
<source><![CDATA[Análise in vitro da contaminação bacteriana na interface implante/conector protético em três sistemas de implantes endósseos]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rimondini]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Marin]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Brunella]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Fini]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Internal contamination of a 2-component implant system after occlusal loading and provisionally luted reconstruction with or without a washer device]]></article-title>
<source><![CDATA[J Periodontol]]></source>
<year>2001</year>
<volume>72</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>1652-7</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sartori]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<source><![CDATA[Avaliação in vitro da capacidade da membrana de silicone vedar a infiltração de bactérias periodontopatogênicas no micro-espaço entre o pilar protético e implantes de hexágono externo]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Proff]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Steinmetz]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Bayerlein]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Dietze]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Fanghanel]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Gedrange]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bacterial colonisation of interior implant threads with and without sealing]]></article-title>
<source><![CDATA[Folia Morphol (Warsz)]]></source>
<year>2006</year>
<volume>65</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>75-7</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Oliani]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<source><![CDATA[Avaliação da eficácia da solução de clorexidina a 2% no controle do desenvolvimento de periodontopatógenos na interface coroa-pilar proético em próteses dentais parafusadas sobre implantes]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Duarte]]></surname>
<given-names><![CDATA[AR]]></given-names>
</name>
<name>
<surname><![CDATA[Rossetti]]></surname>
<given-names><![CDATA[PH]]></given-names>
</name>
<name>
<surname><![CDATA[Rossetti]]></surname>
<given-names><![CDATA[LM]]></given-names>
</name>
<name>
<surname><![CDATA[Torres]]></surname>
<given-names><![CDATA[SA]]></given-names>
</name>
<name>
<surname><![CDATA[Bonachela]]></surname>
<given-names><![CDATA[WC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vitro sealing ability of two materials at five different implant-abutment surfaces]]></article-title>
<source><![CDATA[J Periodontol]]></source>
<year>2006</year>
<volume>77</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>1828-32</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dibart]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Warbington]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Su]]></surname>
<given-names><![CDATA[MF]]></given-names>
</name>
<name>
<surname><![CDATA[Skobe]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vitro evaluation of the implant-abutment bacterial seal: the locking taper system]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>2005</year>
<volume>20</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>732-7</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nascimento]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Barbosa]]></surname>
<given-names><![CDATA[RE]]></given-names>
</name>
<name>
<surname><![CDATA[Issa]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Watanabe]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Ito]]></surname>
<given-names><![CDATA[IY]]></given-names>
</name>
<name>
<surname><![CDATA[Albuquerque Jr]]></surname>
<given-names><![CDATA[RF]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bacterial leakage along the implant-abutment interface of premachined or cast components]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Surg]]></source>
<year>2008</year>
<volume>37</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>177-80</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Norton]]></surname>
<given-names><![CDATA[MR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design]]></article-title>
<source><![CDATA[Clin Oral Implants Res]]></source>
<year>1997</year>
<volume>8</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>290-8</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Norton]]></surname>
<given-names><![CDATA[MR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Assessment of cold welding properties of the internal conical interface of two commercially available implant systems]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1999</year>
<volume>81</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>159-66</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jansen]]></surname>
<given-names><![CDATA[VK]]></given-names>
</name>
<name>
<surname><![CDATA[Conrads]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Richter]]></surname>
<given-names><![CDATA[EJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microbial leakage and marginal fit of the implant-abutment interface]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>1997</year>
<volume>12</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>527-40</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Harder]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Dimaczek]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Acil]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Terheyden]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Freitag-Wolf]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Kern]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Molecular leakage at implant-abutment connection-in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration]]></article-title>
<source><![CDATA[Clin Oral Investig]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pautke]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Kolk]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Brokate]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Wehrstedt]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Kneissl]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Miethke]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Development of novel implant abutments using the shape memory alloy nitinol: preliminary results]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>2009</year>
<volume>24</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>477-83</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De Lorenzo]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Simionato]]></surname>
<given-names><![CDATA[MRL]]></given-names>
</name>
<name>
<surname><![CDATA[Mayu]]></surname>
<given-names><![CDATA[MPA]]></given-names>
</name>
</person-group>
<source><![CDATA[Componentes da microbiota bucal]]></source>
<year>1998</year>
<publisher-loc><![CDATA[São Paulo ]]></publisher-loc>
<publisher-name><![CDATA[Grupo Brasileiro de Microbologia Oral]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nascimento]]></surname>
<given-names><![CDATA[CD]]></given-names>
</name>
<name>
<surname><![CDATA[Pedrazzi]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Miani]]></surname>
<given-names><![CDATA[PK]]></given-names>
</name>
<name>
<surname><![CDATA[Moreira]]></surname>
<given-names><![CDATA[LD]]></given-names>
</name>
<name>
<surname><![CDATA[Junior]]></surname>
<given-names><![CDATA[RFDA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of reapeated screw tigtening on bacterial leakage along the implan-abutment interface]]></article-title>
<source><![CDATA[Clin Oral Implants Res]]></source>
<year>2009</year>
<volume>20</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>394-7</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cury]]></surname>
<given-names><![CDATA[PR]]></given-names>
</name>
<name>
<surname><![CDATA[Horewicz]]></surname>
<given-names><![CDATA[VV]]></given-names>
</name>
<name>
<surname><![CDATA[Augusto]]></surname>
<given-names><![CDATA[ÂO]]></given-names>
</name>
<name>
<surname><![CDATA[Johy]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Laganá]]></surname>
<given-names><![CDATA[DC]]></given-names>
</name>
<name>
<surname><![CDATA[Araújo]]></surname>
<given-names><![CDATA[NS]]></given-names>
</name>
</person-group>
<article-title xml:lang="pt"><![CDATA[Avaliação in vitro da microinfiltração bacteriana na interface impante-intermediário]]></article-title>
<source><![CDATA[Implant News]]></source>
<year>2006</year>
<volume>3</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>613-7</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
