SciELO - Scientific Electronic Library Online

 
vol.13 issue3 author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Revista de Cirurgia e Traumatologia Buco-maxilo-facial

On-line version ISSN 1808-5210

Abstract

PELLIZZER, Eduardo Piza et al. Influence of increasing the length in dental implants. Rev. cir. traumatol. buco-maxilo-fac. [online]. 2013, vol.13, n.3, pp. 87-94. ISSN 1808-5210.

The use of implants of greater length may be more favorable for the predictability of dental implants. This statement is relevant, since the cause of failures in dental implants are more related to biomechanical complications. The aim of this study was to evaluate the influence of increase of the length around the entire body of the implant. Six models were created with the presence of only one hexagonal implant (Master Screw connection, Implant Systems, São Paulo, Brazil) of 3.75 mm x 7.0 mm (Model A), 3.75 mm x 8.5 mm (Model B ), 3.75 mm x 10.0 mm (Model C) 3.75 mm x 11.5 mm (Model D) 3.75 mm x 13.0 mm (Model E) 3.75 mm x 15.0 mm (Model F) using the method of photoelasticity. The results were visualized through a qualitative analysis of stresses (number and intensity photoelastic fringes). The model A showed a pattern of less favorable stress distribution, the oblique loading was the most detrimental to the related structures. Conclusion: The increased length allowed for a better distribution of stresses. The oblique loading was more detrimental when compared to axial loading.

Keywords : Dental Implants; Dental prosthesis; Biomechanics..

        · abstract in Portuguese     · text in Portuguese     · pdf in Portuguese