SciELO - Scientific Electronic Library Online

 
vol.13 issue3 author indexsubject indexarticles search
Home Pagealphabetic serial listing  

RSBO (Online)

On-line version ISSN 1984-5685

Abstract

SILVA-HERZOG, Daniel et al. Fluid-transport evaluation of lateral condensation, GuttaCore™ and continuous wave of obturation techniques. RSBO (Online) [online]. 2016, vol.13, n.3, pp. 171-176. ISSN 1984-5685.

Introduction: To achieve success in endodontic treatment, the root canal system should be as sealed as possible with suitable material such as gutta-percha and sealer. Objective: This study compare the apical leakage of roots obturated with GuttaCore™, lateral condensation, and continuous wave obturation through a computerized fluid-transport system. Material and methods: Fifty-two freshly extracted upper molars were used. The disto-buccal roots were cut and standardized to 10 mm long. The root canals were prepared at working length with WaveOne primary reciprocating files. The specimens were randomly divided and filled by one of the following obturation techniques: GuttaCore™, lateral condensation or continuous wave obturation, using SILCO sealer. The positive controls were left unfilled and the negative controls were totally coated with cyanoacrylate and three layers of nail polish. The roots were stored in relative humidity for 72 h at 37°C, allowing the sealer to set. After this period, the roots were connected to a computerized fluid-transport system, and the apical leakage was analyzed. Results: The results were expressed in μL.cmH2O-1.min-1 x10-4 1.36 atm. The data were statistically analyzed using one-way ANOVA and Tukey´s tests. The specimens of the positive control group showed extreme amounts of apical leakage. There was no leakage in the negative controls. The statistical analysis indicated that continuous wave obturation and GuttaCore™ showed lower leakage than the lateral condensation technique (p<0.05). No difference was found among the continuous wave obturation and GuttaCore™ (p>0.05). Conclusion: Continuous wave obturation and GuttaCore™ showed lower leakage than the lateral condensation technique. There was no difference between the continuous wave obturation and GuttaCore™. The fluidtransport system used in this study allowed an accurate quantitative measurement of leakage using simpler equipment.

Keywords : apical leakage; continuous wave obturation; fluid filtration; fluid transport; guttacore; lateral condensation..

        · text in English     · pdf in English